Richmond water heater pilot light won - The pilot light is an important part of your Rheem water heater, but it might occasionally not light. Usually, relighting the light will restore your water heater’s functionality, but if the light won’t light, there’s a larger issue to address. Contents show 1 1. You Have a Blocked Gas Line 1.1 How To Fix 2 … Rheem Water Heater Pilot Light Won’t Light – Fixed Read More »

 
Reignite the pilot light. Richmond gas heaters use a pilot light to ignite the gas heating the water. Make sure the light hasn't blown out, and if it has, use the ignition mechanism on the heater to light the pilot. Drain and clean the heater. Follow the instructions in Section 2 for draining your Richmond heater and clean the tank and all .... Apartments under dollar1100 near me

The pilot light is an essential part of your Rheem water heater. If it goes out, your water heater wont provide any heat because the pilot light wont ignite the gas to power the heater. This means that you wont be able to light your pilot light. One potential cause of this issue is that you have a blocked gas line.I've got a Richmond Water heater in a 2-flat that is giving me problems. A day ago I got a call that the water wasn't hot anymore so I went over to check it out. The pilot light was out so I lit it by holding down the button and hitting the piezo button. After a few clicks it lit up and stayed lit.Richmond Water Heater Thermocouple Replacement: The How-To Steps. First off, determine which size and style of thermocouple you need for your Richmond water heater. Once you get the correct thermocouple for your water heater, follow the below step-by-step guide to replace the old thermocouple with a new one. 01. Shut Off The Gas SupplyMay 4, 2021 · Water Heater won't stay lit Ruud Water Heater Ph2-40-40f This is a pacemaker with the guardian system. The pilot and burner go out when the gas valve opens. The burner has a flame for a few seconds th … Nov 18, 2022 · The pilot light is an essential part of your Rheem water heater. If it goes out, your water heater wont provide any heat because the pilot light wont ignite the gas to power the heater. This means that you wont be able to light your pilot light. One potential cause of this issue is that you have a blocked gas line. Dec 22, 2022 · Here are the steps to follow: Turn off the gas supply: Locate the gas valve on your water heater and turn it to the “off” position. This will prevent gas from flowing to the pilot light while you work on it. Wait for the water heater to cool down: Give the water heater enough time to cool down before you start working on it. Dec 4, 2018 · Find Thermo couopler for your Water Heater Here: https://www.repairclinic.com/Shop-For-Parts?query=water%20heater%20thermo%20coupleGas water heater pilot not... Sep 14, 2022 · 1. There Is Residual Gas Inside the Unit. Before attempting to ignite your water heater's pilot light, it is important that you turn the gas off and let the unit sit for at least five minutes. This allows any residual gas to disperse from the lines and inside the unit. You don't actually need to shut off the gas valve. May 5, 2022 · I have a Richmond hot water heater with a Honeywell S8610U controller and a Honeywell VR8245M gas valve. The ignition sequence seams to start normally- pilot ignition, main burner ignition- then the m … Sep 3, 2018 · I have a Richmond tankless water heater Model # RMTG-74PVN-1. I have a Richmond tankless water heater Model # XXXXX It was installed the summer of 2007. has operated proplem free until last week when it stopped working and flashing C7 on the remote. May 5, 2022 · I have a Richmond hot water heater with a Honeywell S8610U controller and a Honeywell VR8245M gas valve. The ignition sequence seams to start normally- pilot ignition, main burner ignition- then the m … Jan 17, 2021 · I installed a new Richmond water heater and worked good for like 4 - 5 days. then pilot light went and when i would try to ignite, pilot light would light but as soon as i replaced thermocoupler did t … read more Apr 9, 2020 · I'm not a professional. This is the one thing that's worked AMAZING to get my hot water heater pilot light to stay on! INCREDIBLE prices on AMAZON: https://a... Dec 31, 2015 · 2. If I understand correctly, your pilot flame is lighting correctly. But the main burner won't turn on because the electronics in the Gas Control Valve don't acknowledge the pilot is lit. There are two likely faults: Thermopile is not sensing the flame correctly, or. Circuit Board in the Gas Control Valve is defective. I have a Richmond rmtgl74pvn tankless water heater that has worked great for5 years but it stopped working just now. Won't light, looks like there is no power to the board but I've checked that. read moreJul 29, 2023 · Richmond Water Heater Pilot Light Won’t Stay Lit: A Detailed Discussion. As you can see from the table above, there are many reasons why the heater’s pilot light tends not to stay lit. And there are solutions for each problem. In the following part, I have discussed the issues in more detail and also shared how you can solve them. If your Richmond water heater pilot light won’t stay lit, you will have trouble getting hot water around the house. So the first thing you should do is check the thermocouple. But if the thermocouple is fine, you should check the other things I mentioned in today’s article.A thermocouple is a function on your water heater that senses the heat on the pilot light and allows gas to flow to the burner. A bad thermocouple will shut off gas to both the pilot and the burner, which is when people notice that the water heater pilot light is out. Your water heater pilot light works in concert with other parts.my water heater won't stay onSep 14, 2022 · 1. There Is Residual Gas Inside the Unit. Before attempting to ignite your water heater's pilot light, it is important that you turn the gas off and let the unit sit for at least five minutes. This allows any residual gas to disperse from the lines and inside the unit. You don't actually need to shut off the gas valve. Sep 14, 2022 · 1. There Is Residual Gas Inside the Unit. Before attempting to ignite your water heater's pilot light, it is important that you turn the gas off and let the unit sit for at least five minutes. This allows any residual gas to disperse from the lines and inside the unit. You don't actually need to shut off the gas valve. Sep 4, 2022 · About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ... 5. Flex Tube Defects. This also another possible reason why your pilot’s light won’t come on. The flex tube is how the gas reaches the device, and if the continuous flow of gas is interrupted, the pilot light won’t stay lit. This usually happens when the tube is kinked at one or many points.May 7, 2023 · If you have a Richmond water heater model 6G40-36F3 and you notice that the pilot light won't stay lit, you may be wondering what is causing this problem and how to fix it. In this blog post, we will explain some of the possible reasons why your pilot light keeps going out and what you can do to solve them. Mar 4, 2022 · A water heater pilot lights but not the burner if the thermostat is damaged or over 10 years old. Flame sensors can fail if they are dislodged and the burner won’t detect the pilot light’s flame. Your water heater’s burner won’t work if the gas valve is damaged or the thermostat is unresponsive. Water heater problems often require ... Jan 24, 2023 · January 24, 2023 by David. We’ll cover the following problems in this complete Richmond water heater troubleshooting guide: Condensation. Yellow soot. The main burner won’t light or stay lit. The pilot light won’t stay lit. Rumbling noise. Noise from the relief valve. No hot water or inadequate hot water. Water Heater won't stay lit Ruud Water Heater Ph2-40-40f This is a pacemaker with the guardian system. The pilot and burner go out when the gas valve opens. The burner has a flame for a few seconds th … read moreIf your gas water heater doesn’t stay lit, you may have a defective thermocouple. Most gas fired water heaters use a standing pilot to ignite the main burner. The gas for the pilot assembly is supplied by the main gas valve and is monitored by the thermocouple. The thermocouple is a heat sensing probe that is part of the pilot assembly and ...Aug 5, 2020 · Water Heaters - Weird AO Smith Nat Gas Pilot light issue - I have two 2006 AO Smith 40-gal ProMax gas hot water heaters. I have taken very good care of them, I flush them once a year, change the anode rods as needed, keep them clean, check for backdrafting, etc. Last week one of them had a pilot light out and wouldn't Jan 5, 2006 · Here is what to try. First, using the back end of a large screw driver, medium hard tap the gas control valve. Doing so may dislodge the tiny disk and the pilot will go out. If not, try again. If second attempt fails, turn off the control knob. Turn control dial to the OFF position, so the pilot does go out. I have a Richmond 5v40-7 water heater, we had a flood and I waitted sometime before lighting the polit light.The polit light worked fine, but when I turned up the dial from vacation to warmer after a few minute I would notice some smoke coming from the back of the control unit.I have a Richmond electronic iginition water heater model 5VP40E-1A, sometimes it lights and and works for a few days, sometimes I have to shut it down and then re-start it to get it to work, seen oth …Water heater,,,,6G40S34F3,,,pilot light won't stay lite. 4 years about. Richmond. Just happened today - Answered by a verified HVAC TechnicianI've got a Richmond Water heater in a 2-flat that is giving me problems. A day ago I got a call that the water wasn't hot anymore so I went over to check it out. The pilot light was out so I lit it by holding down the button and hitting the piezo button. After a few clicks it lit up and stayed lit.I have a Richmond tankless water heater Model # RMTG-74PVN-1. I have a Richmond tankless water heater Model # XXXXX It was installed the summer of 2007. has operated proplem free until last week when it stopped working and flashing C7 on the remote.I had a power outage at my house and coincidentally (?) my water heater pilot light went out. My Kenmore water heater is controlled by the Honeywell Gas Valve (part # 9007884), which contains the WV8840 Communication Port. The water heater wouldn’t re-light, but I noticed that the indicator was blinking four times in succession. New Member. May 22, 2013, 08:52 PM. Richmond water heater pilot light won't stay lit. We have a Richmond 40 gal water heater. The sewage pipe in our basement recently overflowed, leaving about 2 inches of water in the basement. Once we got the mess cleaned up, we noticed we have no hot water. We checked the pilot on the hot water heater and ... It is more than likely some kind of high limit sensor which would kick the pilot out should the water heater overheat. If your pilot is not staying lit with a new thermocouple, it may be this sensor. Try jumping the 2 leads going to the thermocouple adapter and see if it remains lit. If it does, it is this sensor that is bad.Here is what to try. First, using the back end of a large screw driver, medium hard tap the gas control valve. Doing so may dislodge the tiny disk and the pilot will go out. If not, try again. If second attempt fails, turn off the control knob. Turn control dial to the OFF position, so the pilot does go out.I had a power outage at my house and coincidentally (?) my water heater pilot light went out. My Kenmore water heater is controlled by the Honeywell Gas Valve (part # 9007884), which contains the WV8840 Communication Port. The water heater wouldn’t re-light, but I noticed that the indicator was blinking four times in succession. I have a Richmond tankless water heater Model # RMTG-74PVN-1. I have a Richmond tankless water heater Model # XXXXX It was installed the summer of 2007. has operated proplem free until last week when it stopped working and flashing C7 on the remote.Replaced Pilot assembly last week as pilot went out when burner shut off. Today I replaced the temperature control valve. Same thing, lit pilot, burner came on the after a heat cycle burner shut off as well as pilot. Trying an immediate restart only igniter worked after about 4 or 5 minutes was able to light the pilot. Then the whole episode ... Sep 23, 2020 · Head down to the water heater to check the pilot and relight it. But first, learn the basics here. By Glenda Taylor and Bob Vila | Updated Sep 23, 2020 9:57 AM If the water heater pilot light will not stay lid there are two main options, the first one is the Thermocouple, but if this one is working fine and you can ... Here is what to try. First, using the back end of a large screw driver, medium hard tap the gas control valve. Doing so may dislodge the tiny disk and the pilot will go out. If not, try again. If second attempt fails, turn off the control knob. Turn control dial to the OFF position, so the pilot does go out.Jan 5, 2006 · Here is what to try. First, using the back end of a large screw driver, medium hard tap the gas control valve. Doing so may dislodge the tiny disk and the pilot will go out. If not, try again. If second attempt fails, turn off the control knob. Turn control dial to the OFF position, so the pilot does go out. Power Vent. Uses indoor air for combustion with flexible venting options up to 100 feet. View Product. Gas. Electric. Speciality. A thermocouple is a function on your water heater that senses the heat on the pilot light and allows gas to flow to the burner. A bad thermocouple will shut off gas to both the pilot and the burner, which is when people notice that the water heater pilot light is out. Your water heater pilot light works in concert with other parts.I have a Richmond hot water heater with a Honeywell S8610U controller and a Honeywell VR8245M gas valve. The ignition sequence seams to start normally- pilot ignition, main burner ignition- then the m …Aug 5, 2020 · Water Heaters - Weird AO Smith Nat Gas Pilot light issue - I have two 2006 AO Smith 40-gal ProMax gas hot water heaters. I have taken very good care of them, I flush them once a year, change the anode rods as needed, keep them clean, check for backdrafting, etc. Last week one of them had a pilot light out and wouldn't richmond tankless gas hot water heater won't run. under the panel the red light was blinking 6 times. But now it is blinking constantly. Before it stopped working, the exhaust vent was clogged with sn …my water heater won't stay onJanuary 24, 2023 by David. We’ll cover the following problems in this complete Richmond water heater troubleshooting guide: Condensation. Yellow soot. The main burner won’t light or stay lit. The pilot light won’t stay lit. Rumbling noise. Noise from the relief valve. No hot water or inadequate hot water.Dec 4, 2018 · Find Thermo couopler for your Water Heater Here: https://www.repairclinic.com/Shop-For-Parts?query=water%20heater%20thermo%20coupleGas water heater pilot not... I had a power outage at my house and coincidentally (?) my water heater pilot light went out. My Kenmore water heater is controlled by the Honeywell Gas Valve (part # 9007884), which contains the WV8840 Communication Port. The water heater wouldn’t re-light, but I noticed that the indicator was blinking four times in succession.The pilot on my Rheem furnace will not stay lit. I have replaced the thermocouple to no avail. The flame looks perfect, nice and blue, the thermocouple gets glowing hot when attempting to light the pilot. I hold the button down in excess of 3 minutes and as soon as you release, the pilot light goes out immediatly.I am not a professional, just documenting how i repaired the hot water heater's pilot light to stay on. The solution was adjusting the thermocouple. You can ...07. Blocked Air Intake End-Note Richmond Water Heater Pilot Light Won’t Stay Lit [7 Easy Solutions] Your Richmond Water Heater pilot light won’t stay lit due to several reasons. These include a bad thermocouple, a tripped limit switch, plugged flammable vapor sensor, and a faulty gas valve.Mar 20, 2022 · The article discusses the common problems that may arise with the Richmond water heater and their troubleshooting. These issues include condensation, yellow flame or soot, failure to light the main burner, rumbling noise, relief valve making popping noise, insufficient or no hot water, and too hot water. The reasons behind each issue and their solutions are elaborated upon in the article. The Richmond Marathon ® water heater offers a LIFETIME warranty. The Marathon is a special water heater that has a seamless blow molded polybutene inner tank. It will not rust. The several inches of foam insulation give it up to 0.93 uniform energy factor. Tank sizes range from 15 gallons to 105 gallons to fit any household need.For use on GE, Rheem, Ruud and Richmond FVIR water heaters with Delta/SIT gas valves; Genuine OEM replacement part; 1 year limited warranty; Fix your water heater with peace of mind using genuine Rheem parts; Easy to install; Call 1-800-432-8373 to ensure this is the correct part for your water heater; Durable construction for long lifeHead down to the water heater to check the pilot and relight it. But first, learn the basics here. By Glenda Taylor and Bob Vila | Updated Sep 23, 2020 9:57 AMFeb 15, 2021 · If your hot water heater has no spark at all, or the flame isn't staying on, give this video a watch for a couple super simple things to try. Repairing your ... We have a Rheem gas water heater model number 21V40-7P. We've just gotten the gas tank refilled, but for some reason, the pilot light went out this morning and the water heater is leaking. I'm trying … read moreThe water heater pilot light is a small flame that ignites the gas burner on your water heater. When the water heater pilot light goes out, first try relighting it, following the directions on the water heater label. If the pilot doesn’t relight, if it goes out right after lighting or if it goes out repeatedly, by far the most common cause is ... Feb 15, 2021 · If your hot water heater has no spark at all, or the flame isn't staying on, give this video a watch for a couple super simple things to try. Repairing your ... Dec 8, 2016 · I have a Richmond rmtgl74pvn tankless water heater that has worked great for5 years but it stopped working just now. Won't light, looks like there is no power to the board but I've checked that. read more Replace the pilot assembly, I do water heater repair, that unit is actually made by A.O. Smith. It’s got a 180 pilot assembly. There is a little round disc that is in the line from the thermocouple that is probably bad and it won’t let the circuit complete.Jul 29, 2023 · Richmond Water Heater Pilot Light Won’t Stay Lit: A Detailed Discussion. As you can see from the table above, there are many reasons why the heater’s pilot light tends not to stay lit. And there are solutions for each problem. In the following part, I have discussed the issues in more detail and also shared how you can solve them. Last night, I noticed that the pilot light was out and this morning when the plumber came to look at it he immediately told me what was wrong with it which is the gas control valve is bad. Said it would cost about $700 to fix so I called Menards and the plumbing associate informed me that the Richmond water heaters have a recall on them for ...Dec 4, 2018 · Find Thermo couopler for your Water Heater Here: https://www.repairclinic.com/Shop-For-Parts?query=water%20heater%20thermo%20coupleGas water heater pilot not... Water heater,,,,6G40S34F3,,,pilot light won't stay lite. 4 years about. Richmond. Just happened today - Answered by a verified HVAC TechnicianHi Ellen I have a Richmond 6G30-32F1 gas hot water heater. that stopped working Thursday. the pilot was out so i lit it and tried to turn it on and everytime i tried to turn it on ot wou;d flameup the …Apr 24, 2011 · I have a Richmond 5v40-7 water heater, we had a flood and I waitted sometime before lighting the polit light.The polit light worked fine, but when I turned up the dial from vacation to warmer after a few minute I would notice some smoke coming from the back of the control unit. Press and hold down on the gas control knob, or pilot set button. At the same time as you’re holding down the pilot switch, press on the piezo igniter. When you click the igniter, you should hear a “click” sound, indicating the spark igniting the pilot. Once the pilot light is on, continue pressing down on the pilot switch for a minute to ...Apr 25, 2010 · I could have found the troubleshooting guide by myself. If you replaced the thermocouple and it will not stay lit there are a couple of possibilities. Make sure the pilot flame envelops approximately 3/8 inch of the tip of the new thermocouple. When you go to light make sure you continue to hold down the button at least 30 seconds after the ... Aug 8, 2018 · My seven year old Richmond 6G40-32PF1 lp gas water heater pilot light won’t stay lit after releasing button. The gas tank ran out of gas and was refilled. It is a sealed system with a window to view the pilot light. New Member. May 22, 2013, 08:52 PM. Richmond water heater pilot light won't stay lit. We have a Richmond 40 gal water heater. The sewage pipe in our basement recently overflowed, leaving about 2 inches of water in the basement. Once we got the mess cleaned up, we noticed we have no hot water. We checked the pilot on the hot water heater and ...So I have a 40 gal Richmond power vent lp water heater. Problem is it doesn't restart So far I have replaced the igniter .I took out the whole water heat and cleaned out the combustion chamber and …May 5, 2022 · I have a Richmond hot water heater with a Honeywell S8610U controller and a Honeywell VR8245M gas valve. The ignition sequence seams to start normally- pilot ignition, main burner ignition- then the m … I've got a Richmond Water heater in a 2-flat that is giving me problems. A day ago I got a call that the water wasn't hot anymore so I went over to check it out. The pilot light was out so I lit it by holding down the button and hitting the piezo button. After a few clicks it lit up and stayed lit.1. Turn the gas valve to the "Pilot" setting and push down on it. Doing this starts the flow of gas into the tube that supplies the pilot light. If your water heater’s gas valve does not push down, look for a red control button near the valve. Hold this button down.Mar 4, 2022 · A water heater pilot lights but not the burner if the thermostat is damaged or over 10 years old. Flame sensors can fail if they are dislodged and the burner won’t detect the pilot light’s flame. Your water heater’s burner won’t work if the gas valve is damaged or the thermostat is unresponsive. Water heater problems often require ... I'm not a professional. This is the one thing that's worked AMAZING to get my hot water heater pilot light to stay on! INCREDIBLE prices on AMAZON: https://a...The pilot light is an important part of your Rheem water heater, but it might occasionally not light. Usually, relighting the light will restore your water heater’s functionality, but if the light won’t light, there’s a larger issue to address. Contents show 1 1. You Have a Blocked Gas Line 1.1 How To Fix 2 … Rheem Water Heater Pilot Light Won’t Light – Fixed Read More »Review Hoffmann Brothers' guide for how to light your water heater pilot light, perform basic checks, troubleshoot and access info for your specific brand. Careers (314) 664-3011 Book Now Air ConditioningReplaced Pilot assembly last week as pilot went out when burner shut off. Today I replaced the temperature control valve. Same thing, lit pilot, burner came on the after a heat cycle burner shut off as well as pilot. Trying an immediate restart only igniter worked after about 4 or 5 minutes was able to light the pilot. Then the whole episode ... New Member. May 22, 2013, 08:52 PM. Richmond water heater pilot light won't stay lit. We have a Richmond 40 gal water heater. The sewage pipe in our basement recently overflowed, leaving about 2 inches of water in the basement. Once we got the mess cleaned up, we noticed we have no hot water. We checked the pilot on the hot water heater and ... Replaced Pilot assembly last week as pilot went out when burner shut off. Today I replaced the temperature control valve. Same thing, lit pilot, burner came on the after a heat cycle burner shut off as well as pilot. Trying an immediate restart only igniter worked after about 4 or 5 minutes was able to light the pilot. Then the whole episode ... 6. Below is a picture of the lighting instructions for your water heater taken from Rheem's website. Make sure to follow the lighting instructions carefully and do not skip any steps. This same instruction set should be available as a sticker on your unit. It looks like you do in fact have to depress the knob in order to turn it so avoid using ...May 24, 2013 · I am not a professional, just documenting how i repaired the hot water heater's pilot light to stay on. The solution was adjusting the thermocouple. You can ...

By Vikram May 7, 2023 If you have a Richmond water heater model 6G40-36F3 and you notice that the pilot light won’t stay lit, you may be wondering what is causing this problem and how to fix it. In this blog post, we will explain some of the possible reasons why your pilot light keeps going out and what you can do to solve them.. Accuweather 90 day forecast 2022

richmond water heater pilot light won

Remove the access panel to access the burner. Turn the knob to “Pilot” to start the flow of gas. You’ll want to press and hold the knob down. While still holding the gas knob, light the pilot with a long lighter. If your gas water heater has an igniting button, press that instead. Once ignited, release and turn the gas knob to the “On ...Water heater,,,,6G40S34F3,,,pilot light won't stay lite. 4 years about. Richmond. Just happened today - Answered by a verified HVAC TechnicianJun 26, 2007 · I've got a Richmond Water heater in a 2-flat that is giving me problems. A day ago I got a call that the water wasn't hot anymore so I went over to check it out. The pilot light was out so I lit it by holding down the button and hitting the piezo button. After a few clicks it lit up and stayed lit. So I have a 40 gal Richmond power vent lp water heater. Problem is it doesn't restart So far I have replaced the igniter .I took out the whole water heat and cleaned out the combustion chamber and …Review Hoffmann Brothers' guide for how to light your water heater pilot light, perform basic checks, troubleshoot and access info for your specific brand. Careers (314) 664-3011 Book Now Air Conditioning Jun 17, 2018 · my water heater won't stay on I have a Richmond 5v40-7 water heater, we had a flood and I waitted sometime before lighting the polit light.The polit light worked fine, but when I turned up the dial from vacation to warmer after a few minute I would notice some smoke coming from the back of the control unit.Water heater pilot is not on; no hot water. Serial No. Q132038894. Model No. 6G40-36F3. I've tried to start the pilot light without success. The instructions affixed on the heater and the instructions … read morePower Vent. Uses indoor air for combustion with flexible venting options up to 100 feet. View Product. Gas. Electric. Speciality. I have a Richmond electronic iginition water heater model 5VP40E-1A, sometimes it lights and and works for a few days, sometimes I have to shut it down and then re-start it to get it to work, seen oth …It's easy to fix this water heater problem by yourself. I fixed mine and also decided to make a better video to help out more people who love DIY.- Pilot lig...5. Flex Tube Defects. This also another possible reason why your pilot’s light won’t come on. The flex tube is how the gas reaches the device, and if the continuous flow of gas is interrupted, the pilot light won’t stay lit. This usually happens when the tube is kinked at one or many points. The Richmond Marathon ® water heater offers a LIFETIME warranty. The Marathon is a special water heater that has a seamless blow molded polybutene inner tank. It will not rust. The several inches of foam insulation give it up to 0.93 uniform energy factor. Tank sizes range from 15 gallons to 105 gallons to fit any household need.Jun 10, 2022 · It's not always the thermocouple that is faulty. Many of these gas control valves can be easily fixed!! This is a very quick fix that anyone can do without c... I am not a professional, just documenting how i repaired the hot water heater's pilot light to stay on. The solution was adjusting the thermocouple. You can ...If your gas water heater doesn’t stay lit, you may have a defective thermocouple. Most gas fired water heaters use a standing pilot to ignite the main burner. The gas for the pilot assembly is supplied by the main gas valve and is monitored by the thermocouple. The thermocouple is a heat sensing probe that is part of the pilot assembly and ...I installed a new Richmond water heater and worked good for like 4 - 5 days. then pilot light went and when i would try to ignite, pilot light would light but as soon as i replaced thermocoupler did t … read moreLast night, I noticed that the pilot light was out and this morning when the plumber came to look at it he immediately told me what was wrong with it which is the gas control valve is bad. Said it would cost about $700 to fix so I called Menards and the plumbing associate informed me that the Richmond water heaters have a recall on them for ...I am not a professional, just documenting how i repaired the hot water heater's pilot light to stay on. The solution was adjusting the thermocouple. You can ....